Skip to main content
Version: v2.6.x LTS

zwe components install extract

zwe components install extract

zwe > components > install > extract

zwe components install extract [parameter [parameter]...]

Description​

Extract module package and lay down to target directory.

NOTE: this sub-command will be automatically executed by zwe components install, so usually you don't need to execute this manually.

Examples​

zwe components install extract -c /path/to/zowe.yaml -o /path/to/component/package

Parameters​

Full nameAliasTypeRequiredHelp message
--component-file,--component-ostringyesPath to the component package or directory.
--auto-encoding-estringnoIf we want to automatically tagging the module files.

Inherited from parent command​

Full nameAliasTypeRequiredHelp message
--help-hbooleannoDisplay this help.
--debug,--verbose-vbooleannoEnable verbose mode.
--trace-vvbooleannoEnable trace level debug mode.
--silent-sbooleannoDo not display messages to standard output.
--log-dir,--log-lstringnoWrite logs to this directory.
--config-cstringnoPath to Zowe configuration zowe.yaml file.
--configmgrbooleannoEnable use of configmgr capabilities.

Errors​

Error codeExit codeError message
ZWEL0139E139Failed to create directory %s.
ZWEL0153E153Cannot install Zowe component to system root directory.
ZWEL0154E154Temporary directory is empty.
ZWEL0155E155Component %s already exists in %s.
ZWEL0167E167Cannot find component name from %s package manifest.
ZWEL0204E204Symlink creation failure, error=%s
ZWEL0313E313Cannot file component file %s.### Inherited from parent command
Error codeExit codeError message
ZWEL0156E156Component name is not initialized after extract step.
ZWEL0180E180Zowe extension directory (zowe.extensionDirectory) is not defined in Zowe YAML configuration file.
ZWEL0304E304Handler install failure, cannot continue.
ZWEL0305E305Could not find one of the components' directories.
ZWEL0314E314Cannot install with component=all. This option only exists for upgrade.
ZWEL0315E315Handler (-handler or zowe.extensionRegistry.defaultHandler) required but not specified.
ZWEL0101E101ZWE_zowe_runtimeDirectory is not defined.
ZWEL0102E102Invalid parameter %s.
ZWEL0103E103Invalid type of parameter %s.
ZWEL0104E104Invalid command %s.
ZWEL0105E105The Zowe YAML config file is associated to Zowe runtime "%s", which is not same as where zwe command is located.
ZWEL0106E106%s parameter is required.
ZWEL0107E107No handler defined for command %s.
ZWEL0108E108Zowe YAML config file is required.
ZWEL0109E109The Zowe YAML config file specified does not exist.
ZWEL0110E110Doesn't have write permission on %s directory.
ZWEL0111E111Command aborts with error.
ZWEL0112E112Zowe runtime environment must be prepared first with "zwe internal start prepare" command.
ZWEL0114E114Reached max retries on allocating random number.
ZWEL0120E120This command must run on a z/OS system.
ZWEL0121E121Cannot find node. Please define NODE_HOME environment variable.
ZWEL0122E122Cannot find java. Please define JAVA_HOME environment variable.
ZWEL0123E123This function is only available in Zowe Containerization deployment.
ZWEL0131E131Cannot find key %s defined in file %s.
ZWEL0132E132No manifest file found in component %s.
ZWEL0133E133Data set %s already exists.
ZWEL0134E134Failed to find SMS status of data set %s.
ZWEL0135E135Failed to find volume of data set %s.
ZWEL0136E136Failed to APF authorize data set %s.
ZWEL0137E137z/OSMF root certificate authority is not provided (or cannot be detected) with trusting z/OSMF option enabled.
ZWEL0138E138Failed to update key %s of file %s.
ZWEL0139E139Failed to create directory %s.
ZWEL0140E140Failed to translate Zowe configuration (%s).
ZWEL0142E142Failed to refresh APIML static registrations.
ZWEL0172EComponent %s has %s defined but the file is missing.
ZWEL0200EFailed to copy USS file %s to MVS data set %s.
ZWEL0201EFile %s does not exist.
ZWEL0202EUnable to find samplib key for %s.
ZWEL0203EEnv value in key-value pair %s has not been defined.
ZWEL0316ECommand requires zowe.useConfigmgr=true to use.